English
Classified as a full-azimuth directional acoustic alert unit, the RX1060A achieves a practical warning coverage radius of 1,323 meters, with a total covered alert territory spanning 5.49 km². It serves regional voice broadcasting and urgent alarm triggering work across large-scale sites including island territories, woodland zones, grassland basins and airport premises. A reserved TCP/IP network interface unlocks remote monitoring and parameter adjustment, fully satisfying operational requirements for centralized mass emergency notification workflows.
The RX1060A generates uniform horizontal sound distribution covering a total zone of 5.49 km². Its peak sound pressure value reaches 149 dBA measured at a one-meter distance, guaranteeing complete audible signal penetration across the entire deployed service zone.
Field staff can launch instant voice live announcements with handheld microphone hardware, alongside native onboard audio playback and saved recording loop playback operational modes.
Its calibrated frequency response band ranges from 250 Hz up to 7000 Hz. This technical specification fulfills diversified practical tasks including manual voice announcements, scheduled broadcast playback, pre-emptive early warning signaling, emergency alarm triggering, bird flock repulsion and wild fauna directional relocation guidance.
Integrated with a TCP/IP network communication port, users may execute direct remote manipulation via dedicated control terminals. The hardware also supports seamless docking with legacy security supervision platforms and hierarchical command dispatch systems.
The product passes full-item MIL-STD-810H military standard qualification testing and holds an IP65 protection grade, maintaining steady long-duration operation under erratic extreme weather and geographically harsh field environments.
Matched with a purpose-built power distribution cabinet, the machine accepts alternating current input fluctuating between 110V and 260V. It achieves seamless compatibility with international regional power grid standards and effectively counteracts adverse impacts brought by unpredictable voltage swings.
Parameter | Details |
Peak SPL@1m | 149dBA |
Continuous SPL@1m | 143dBA |
Continuous SPL@30m | 113dBA |
Notification Radius | 1323m |
Notification Area | 5.49km² |
Dimension(D*H) | 700mm*1120mm |
Weight | 73kg |
IP Rating | IP65 |
What installation methods does this product support?
The RX1060A adopts fixed permanent mounting onto high, unobstructed locations such as signal towers, overhead power poles and building rooftop platforms.
In what environments can this product be used?
With a functional temperature bracket set between -40°C and +50°C, IP65 enclosure protection and inherent salt spray corrosion resistance, this acoustic device suits deployment on offshore wind energy platforms, fishing operational waters, remote islands, prairie terrain, gobi desert zones, ultra-high altitude plateaus and extreme latitude climate zones.
Does it support a dry contact interface?
A dedicated dry contact signal interface comes standard, facilitating smooth signal linkage with third-party external security defense and emergency alarm hardware systems.
Does it support electrical cabinets?
A supporting power control cabinet is equipped centrally, sustaining orderly emergency alarm system scheduling and stable long-term operational status.
What voice interaction methods does this product support?
Operators deliver live voice broadcast content through handheld microphone hardware. Users may select our factory-standard microphone model or adopt alternative third-party microphone devices compliant with designated communication protocol rules.
What are the control methods for this product?
Operating upon the TCP/IP protocol framework, multiple management channels remain accessible. Operators run direct control via official dedicated terminals and portable handheld tablets, or embed hardware equipment inside customer-owned security platforms and command dispatch systems.
Does this product support OEM/ODM customization?
Comprehensive OEM and ODM customized development programs are accessible. Adjustable custom content covers operation display languages, outer housing color schemes and printed equipment identification nameplates. Customized development extends to core functional modules: LED warning lamp assemblies, one-touch shortcut control keys, fixed alert phrase libraries with multilingual translation, personalized operation interface layouts and targeted technical parameter recalibration. Customized bundled service packages can be formulated according to personalized project-level product demands.
The RX1060A focuses entirely on centralized mass emergency notification workflows. Balanced hardware performance paired with moderate warning coverage makes this unit particularly well-suited for island public address network construction, undertaking perimeter intrusion trigger alarms, routine broadcast notifications and natural disaster emergency early warning tasks.
